1.1 These test methods specify procedures and equipment used for testing and evaluating a motorized treadmill for compliance to Specification F 2115. Both design and operational parameters will be evaluated. Where possible and applicable, accepted test methods from other recognized bodies will be used and referenced. In case of a conflict between this document and specification F 2115, the Specification F 2115 takes precedence.
1.2 Requirements—A motorized treadmill is to be tested for all of the following parameters:
1.2.1 Stability,
1.2.2 Exterior design,
1.2.3 Endurance,
1.2.4 Static loading,
1.2.5 Overheating,
1.2.6 Adjustable incline system function,
1.2.7 User interface parameters,
1.2.8 Motorized drive system operation,
1.2.9 Warning label compliance, and
1.2.10 Documentation.