Creasing of membrane switches or their components can affect their visual appearance, mechanical integrity or electrical functionality. This practice simulates conditions that may be seen during manufacture, installation or use.
Crease testing may be destructive, therefore any samples tested should be considered unfit for future use.
Specific areas of testing include, but are not limited to:
Membrane switch flex tails, and
Any component of a membrane switch that may be subjected to bending.
Область применения1.1 This test method establishes a method for the creasing of any part of a membrane switch with conductive circuits.
1.1.1 The values given in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.