Formerly under the jurisdiction of Committee F16 on Fasteners, this specification was withdrawn in November 2023. This standard is being withdrawn without replacement because these products are better covered by ISO 3506-1.
РефератThis specification covers the chemical and mechanical requirements for stainless steel metric hexagon socket button (SBHCS) and flat countersunk (SFHCS) head cap screws with nominal thread M 3 through M 20 intended for use in applications requiring general corrosion resistance. These steels are designated into three classes: Austenitic Class A 1-50 in an annealed condition, Austenitic Class A1-55 in a cold worked condition, and Austenitic Class A 1-70 in a cold worked condition. The austenitic stainless steel socket screw shall be designated F879M A1-50, F879M A1–55, or F 879M A1-70. Screws shall be formed by upsetting or extruding, or both. Also, these screws shall be roll threaded. Austenitic alloys ClassA 1-50 screws, following manufacture, shall be annealed by heating to a certain temperature to obtain maximum corrosion resistance and minimum permeability. The screws shall be held for a sufficient time at temperature, then cooled at a rate sufficient to prevent precipitation of the carbide and provide the properties specified. Different tests shall be conducted in order to determine the following mechanical properties of screws: tensile strength, minimum extension, yield strength, elongation, Vickers hardness, and Rockwell hardness.
Область применения1.1 This specification covers the chemical and mechanical requirements for stainless steel metric hexagon socket button (SBHCS) and flat countersunk (SFHCS) head cap screws with nominal thread M 3 through M 20 intended for use in applications requiring general corrosion resistance.
1.2 The following three property classes are covered:
1.2.1 Austenitic Class A1-50 in an annealed condition at 585 MPa maximum,
1.2.2 Austenitic Class A1–55 in a cold worked condition at 550 MPa minimum, and
1.2.3 Austenitic Class A1-70 in a cold-worked condition at 700 MPa minimum.
1.3 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 The following hazard caveat pertains only to Section 12, Test Methods: This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.