This test method describes the nondestructive measurement of the thickness of a dry, nonmagnetic coating applied to the external surface of steel pipe. The method is recommended for coating thicknesses up to 6 mm (0.240 in.) and for any diameter pipe, but not smaller than 10 mm (0.5 in.). It does not apply to excessively soft films.
Formerly under the jurisdiction of Committee D01 on Related Coatings, Materials, and Applications, this test method was withdrawn in March 2007 in accordance with section 10.5.3.1 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.
Область применения1.1 This test method describes the nondestructive measurement of the thickness of a dry, nonmagnetic coating applied to the external surface of steel pipe. The method is recommended for coating thicknesses up to 6 mm (0.240 in.) and for any diameter pipe, but not smaller than 10 mm (0.5 in.). It does not apply to excessively soft films.
1.2 The values stated in SI units to three significant decimals are to be regarded as the standard.
1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.