Insulating and sheathing materials of electric cables. Common test methods, Methods specific to PVC compounds, Loss of mass test. Thermal stability test— 18 стр.
Electric and optical fibre cables. Test methods for non-metallic materials. Miscellaneous tests. Thermal ageing methods. Ageing in an air bomb— 14 стр.
Electric and optical fibre cables. Test methods for non-metallic materials. Miscellaneous tests. Thermal ageing methods. Ageing in an air oven— 22 стр.
Railway applications. Railway rolling stock high temperature power cables having special fire performance. Single core silicone rubber insulated cables for 120$0DC or 150$0DC— 28 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV to 33 kV. Three-core 11 kV cables— 28 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV. Single-core 33 kV lead sheathed cables— 26 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation of rated voltages of 11 kV to 33 kV. Single-core 11 kV to 33 kV cables— 32 стр.
Railway applications. Railway rolling stock high temperature power cables having special fire performance. Single core silicone rubber insulated cables for 120 $0DC or 150 $0DC— 28 стр.
Railway applications. Railway rolling stock power and control cables having special fire performance. Cables with crosslinked elastomeric insulation with reduced dimensions. Multicore cables— 36 стр.
Railway applications. Railway rolling stock power and control cables having special fire performance. Cables with crosslinked elastomeric insulation with reduced dimensions. Single core cables— 28 стр.
Railway applications. Railway rolling stock power and control cables having special fire performance. Cables with crosslinked elastomeric insulation. Multicore cables— 32 стр.
Railway applications. Railway rolling stock power and control cables having special fire performance. Cables with crosslinked elastomeric insulation. Single core cables— 28 стр.
Electric and optical fibre cables. Test methods for non-metallic materials. Miscellaneous tests. Thermal ageing methods. Ageing in an air bomb— 14 стр.
Multi-pair cables used in high bit rate digital access telecommunications networks. Indoor multi-pair/quad riser cables up to 100 MHz for maximum length of connection 100 m supporting universal services, xDSL and applications up to 100 Mbit/s over IP— 18 стр.
Electric and optical fibre cables. Test methods for non-metallic materials. Miscellaneous tests. Thermal ageing methods. Ageing in an air oven— 22 стр.
Specification for 600/1000 V single-phase split concentric electric cables, Cables having thermosetting insulation and low emission of smoke and corrosive gases when affected by fire— 22 стр.
Insulating and sheathing materials of electric cables. Common test methods. General application, Measurement of thickness and overall dimensions. Tests for determining the mechanical properties, Section 1: Measurement of thickness and overall dimensions - Tests for determining the mechanical properties— 28 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground, Single wire armoured and PVC sheathed multicore cable with copper conductors, having reduced fire propagation performance, Section 8.3 Single wire armoured and PVC sheathed multicore cable with copper conductors, having reduced fire propagation performance— 20 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities, Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated, copper wire waveform or helical concentric cables with solid aluminium conductors, having low emission of smoke and corrosive gases when affected by fire. (Implementation of HD 603)— 16 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities, Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated, copper wire waveform or helical concentric cables with solid aluminium conductors, having low emission of smoke and corrosive gases when affected by fire— 22 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV, Single-core 33 kV lead sheathed cables, Single core 33 kV lead sheathed cables— 16 стр.
Electric cables. Flexible cords rated up to 300/500 V, for use with appliances and equipment intended for domestic, office and similar environments— 60 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for 0.6/1 kV and 1.9/3.3 kV power cables with special fire performance for use in power stations, PVC insulated and PVC sheathed cables— 40 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for power cables having rated voltages of 3.8/6.6 kV and 6.35/11 kV with special fire performance for use in power stations, Single-core and 3-core cables with halogen-free materials and with aluminium or steel wire armouring— 30 стр.
Electric cables. Thermosetting insulated, non-armoured cables for voltages up to and including 450/750 V, for electric power, lighting and internal wiring, and having low emission of smoke and corrosive gases when affected by fire— 30 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV, XLPE insulated, copper wire waveform concentric cables with solid aluminium conductors— 14 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground, Single wire armoured and unarmoured multicore cables with copper conductors and non-halogenated sheath, Section 8.5 Single wire armoured and unarmoured multicore cables with copper conductors and non-halogenated sheath— 28 стр.
Electric cables. Thermosetting insulated, armoured cables for voltages of 600/1000 V and 1900/3300 V, having low emission of smoke and corrosive gases when affected by fire— 48 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities, Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated split concentric cables with copper or aluminium conductors— 22 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV, XLPE insulated split concentric cables with copper or aluminium conductors— 16 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV, XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors— 16 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV, PVC insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors— 16 стр.
Power cables with XLPE insulation and metallic sheath, and their accessories, for rated voltages from 66 kV ($iU$dm=72.5 kV) to 132kV ($iU$dm=145kV). Requirements and test methods— 46 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities, Specification for 0.6/1 kV and 1.9/3.3 kV power cables with special fire performance for use in power stations, XLPE or HEPR insulated and PVC sheathed cables— 40 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for power cables having rated voltages of 3.8/6.6 kV and 6.35/11 kV with special fire performance for use in power stations, Single core and 3-core cables with halogenated materials and with aluminium or steel wire armouring— 26 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV, Single-core 11 kV and 33 kV cables, Single core 11 kV and 33 kV cables— 20 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV, Three-core 11 kV cables, Three core 11 kV cables— 20 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV, PVC insulated split concentric cables with copper or aluminium conductors— 14 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground, Single wire or double steel tape armoured and non-halogenated sheathed multipair cable with copper conductors, Section 8.6 Single wire or double steel tape armoured and non-halogenated sheathed multipair cable with copper conductors— 28 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities, Specification for distribution cables with extruded insulation for rated voltages of 11 kV to 33 kV, Three-core 11 kV cables (Implementation of HD 620)— 28 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities, Polymeric insulated aerial bundled conductors (ABC) of rated voltage 0.6/1 kV for overhead distribution— 16 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities, Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated split concentric cables with copper or aluminium conductors, having low emission of smoke and corrosive gases when affected by fire— 24 стр.
Electric cables. PVC insulated, non-armoured cables for voltages up to and including 450/750 V, for electric power, lighting and internal wiring— 48 стр.
Elastomer insulated fire resistant (limited circuit integrity) cables for fixed wiring in ships and on mobile and fixed offshore units. Requirements and test methods— 46 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities, Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors, having low emission of smoke and corrosive gases when affected by fire— 22 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities, Specification for distribution cables of rated voltage 0.6/1 kV, XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors, having low emission of smoke and corrosive gases when affected by fire— 16 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities, Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV, Single-core 33 kV lead sheathed cables (Implementation of HD 620)— 26 стр.
Electric cables. Armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 kV to 19/33 kV having low emission of smoke and corrosive gases when affected by fire. Requirements and test methods— 64 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities, Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors— 20 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities, Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated, copper wire waveform concentric cables with solid aluminium conductors— 20 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities, Polymeric insulated aerial bundled conductors (ABC) of rated voltage 0.6/1 kV for overhead distribution— 22 стр.
LV and MV polymeric insulated cables for use by distribution and generation utilities, Specification for distribution cables with extruded insulation of rated voltages of 11 kV to 33 kV, Single-core 11 kV to 33 kV cables (Implementation of HD 620)— 32 стр.
Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables (english version)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-12: Cables for general applications - Cables with thermoplastic PVC insulation for extensible leads (english version)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-41: Cables for general applications - Single core cables with crosslinked silicone rubber insulation (english version)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation (english version)
Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables (english version)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-82: Cables for general applications - Cables with crosslinked elastomeric insulation for decorative chains (english version)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-81: Cables for general applications - Cables with crosslinked elastomeric covering for arc welding (english version)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke (english version)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-83: Cables for general applications - Multicore cables with crosslinked silicone rubber insulation (english version)
Communication cables - Part 2-27: Common design rules and construction - Halogen free flame retardant thermoplastic sheathing compounds (english version)