This European Standard specifies a room method for the measurement of the pollutant concentration
parameter of a specified airborne hazardous substance from machines, located in a test room and operating
the machines under defined conditions.
This method can only be used for machines with a local exhaust ventilation with an air flow rate ≥ 500 m3/h
and machines without recirculated air.
Measurement of the pollutant concentration parameter of a machine can serve for the:
a) evaluation of the performance of a machine;
b) evaluation of the improvement of the machine;
c) comparison of machines within groups of machines with the same intended use (groups are defined by
the function and materials processed);
d) ranking of machines from the same group according to their pollutant concentration parameters;
e) determination of the state of the art of machines with respect to their pollutant concentration parameter.
Diese Europäische Norm legt ein Verfahren zur Messung des Konzentrationsparameters eines festgelegten
luftgetragenen Gefahrstoffes von Maschinen, die in einem Prüfraum aufgestellt und unter bestimmungsgemäßen
Bedingungen betrieben werden, fest.
Dieses Verfahren kann nur für Maschinen mit einem Absaugung-Volumenstrom ≥ 500 m3/h angewendet
werden.
Die Messung des Konzentrationsparameters des luftverunreinigenden Stoffes einer Maschinen kann dienen:
a) zur Bewertung des Betriebsverhaltens einer Maschine;
b) zur Bewertung von Verbesserungsmaßnahmen an der Maschine;
c) zum Vergleichen von Maschinen innerhalb von Maschinengruppen mit der gleichen
bestimmungsgemäßen Verwendung (die Gruppen werden definiert nach der Maschinenfunktion und nach
den bearbeiteten Materialien);
d) zum Einordnen von Maschinen aus der gleichen Gruppe entsprechend ihrem Konzentrationsparameter;
e) zum Bestimmen des Standes der Technik der Maschinen in Bezug auf ihren Konzentrationsparameter.