ÖNORM EN 12309-2:2000-04

Заменен
Gas-fired absorption and adsorption air-conditioning and/or heat pump appliances with a net heat input not exceeding 70 kW - Part 2: Rational use of energy
This European standard specifies the requirements and methods of test for the rational use of energy of gas-fired absorption and adsorption air conditioning and/or heat pump appliances having a net heat input not exceeding 70 kW, hereafter referred to as "appliances". This standard applies to appliances having flue systems of Type B , B , B , B , B , B , 12 12BS 13 13BS 14 22
B , C , C , C and C , and to appliances designed for outdoor installations.
This standard only applies to appliances having: integral burners under the control of fully automatic burner control systems; closed system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated; mechanical means to assist transportation of the combustion air and/or the flue gases.
Appliances covered by this standard include one or a combination of the following: gas-fired absorption air conditioner; gas-fired adsorption air conditioner; gas-fired absorption heat pump; gas-fired adsorption heat pump.
The above appliances can have one or more primary or secondary functions (see 3.5 and 3.6) and this standard applies to all such functions providing that the function concerned is dependent on
circulation of fluid within the absorption, or adsorption, refrigerant circuit.
NOTE Any appliance function that is not dependent on circulation of the fluid within the absorption, or adsorption, refrigerant circuit should be assessed separately.
This standard does not apply to appliances fitted with more than one flue outlet.
This standard is applicable to appliances that are intended to be type tested. Requirements for appliances that are not type tested would need to be subject to further consideration.
Die vorliegende Norm legt Anforderungen und Prüfverfahren für die rationelle Energieanwendung von gasbefeuerten Sorptions-Luftkonditionierern und/oder - Wärmepumpen mit einer Nennwärmebelastung bis 70 kW fest. Diese Norm gilt ausschließlich für Geräte mit integrierten Brennern unter Kontrolle von Gasfeuerungsautomatenund mit geschlossenen Kühlkreislaufsystemen, in denen das Kühlmittel nicht direkt mit dem zu kühlenden oder zu erwärmenden Wasser oder Luft in Berührung kommt, sowie mit mechanischen Einrichtungen zur Unterstützung des Verbrennungsluft- und/oder Abgastransports.
ICS
23.120 Ventilators. Fans. Air-conditioners / Вентиляторы. Фены. Кондиционеры
27.080 Heat pumps / Тепловые насосы