This document specifies specific requirements on automated measuring systems (AMS) for dust monitoring. It
is derived from EN 14181 which is the general document on the quality assurance of AMS. It is only applicable
in conjunction with EN 14181.
This document specifies test criteria for the QAL1 and specific requirements for QAL2, QAL3 and AST for dust
AMS used for proving that the dust emissions from a source are compliant with emission limits below
50 mg/m3 (standard conditions) in ducted gaseous streams. This document is applicable by direct correlation
with the standard reference method (SRM) described in EN 13284-1.
This document is primarily developed for emissions from waste incinerators. From a technical point of view, it
may be applied to other processes, for which measurement at an emission limit is required with defined
uncertainty.
Dieser Teil der Europäischen Norm legt Bedingungen und Kriterien für die Auswahl, Inbetriebnahme und Kalibrierung von automatischen Messeinrichtungen (AMS) fest, die zum Nachweis eingesetzt werden, dass die Emissionen einer Quelle Emissionsgrenzwerte unterhalb von 50 mg/m³ (Normbedingungen) in geführten Abgasströmen einhalten. Teil 2 der Norm ist anlagenspezifisch anwendbar durch direkten Vergleich mit dem manuellen Referenzmessverfahren nach Teil 1 der Norm. Teil 2 der Norm wurde insbesondere zur Ermittlung von Emissionen aus Müllverbrennungsanlagen entwickelt. Aus technischer Sicht kann diese Norm auch auf andere Prozesse angewandt werden. Die Norm basiert auf dem allgemeinen Dokument zur Qualitätssicherung automatischer Messeinrichtungen (prEN 14181) und muss zusammen mit diesem Dokument angewandt werden.