This document specifies particle filters for use as replaceable components in unassisted respiratory protective devices (RPD) with the exception of escape devices and filtering face pieces.
Laboratory tests are included for the assessment of compliance with the requirements.
Some filters complying with this document can also be suitable for use with other types of respiratory protective devices and/or escape devices. If so, they need to be tested and marked according to the appropriate European Standard.
This document does not cover requirements concerning respiratory hygiene. Requirements for decrease of the microbiological hazards caused by the growth of bacteria and viruses on the filtration material are not determined.
Dieses Dokument spezifiziert Partikelfilter zur Verwendung als austauschbare Bestandteile von Atemschutzgeräten (ASG) ohne Luftversorgung mit der Ausnahme von Fluchtgeräten und filtrierenden Atemanschlüssen.
Laborprüfungen sind enthalten, um die Übereinstimmung mit den Anforderungen feststellen zu können.
Einige Filter, die diesem Dokument entsprechen, können auch für die Verwendung mit anderen Typen von Atemschutzgeräten und/oder Fluchtgeräten geeignet sein. Falls dies zutrifft, müssen sie gemäß der entsprechenden Europäischen Norm geprüft und gekennzeichnet werden.
Dieses Dokument enthält keine Anforderungen an die Atemhygiene. Die Anforderungen zur Verringerung der mikrobiologischen Gefahren, die durch das Wachstum von Bakterien und Viren auf dem Filtrationsmaterial verursacht werden, werden nicht bestimmt.