This document specifies a test method to establish the uplift resistance of installed clay or concrete tiles for
roofing, complying with the relevant product standard, EN 490 or EN 1304, which are unfixed or mechanically
fixed to the substructure.
NOTE The test method has been developed for clay or concrete tiles for roofing but may apply to other
discontinuously laid small elements, such as: slates; fibre cement slates; and, stones.
The test method is applicable to mechanical fixings such as clips, hooks, screws and nails.
In case of mechanically fixed tiles, at least every third tile shall be fixed. The method is not applicable for fixed
tiles with fixing patterns with less than every third tile fixed.
The test method is not applicable to under and over tiles. Examples of these tiles are given in Annex H.
Diese ÖNORM legt ein Prüfverfahren zur Ermittlung des Abhebewiderstandes von Dachziegeln oder Dachsteinen nach EN 490 bzw. EN 1304, die entweder unbefestigt oder mechanisch an der Unterkonstruktion befestigt sind, fest. Das Prüfverfahren gilt für mechanische Befestigungen wie Klammern, Haken, Schrauben und Nägel. Bei mechanisch befestigten Ziegeln muss mindestens jeder dritte Ziegel befestigt werden. Das Prüfverfahren gilt nicht für befestigte Ziegel mit Befestigungsmustern, bei denen weniger als jeder dritte Ziegel befestigt ist. Das Prüfverfahren ist nicht anwendbar für Mönch- und Nonnen-Ziegel. Beispiele für solche Ziegel sind in Anhang H angegeben. Das Prüfverfahren wurde für Dachziegel oder Dachsteine entwickelt, es ist jedoch anwendbar auch für andere überlappend verlegte kleine Dachelemente wie z.B. Schiefer, Faserzementplatten und Natursteine.