This European Standard specifies a continuous measurement method for the determination of the concentration of
carbon monoxide present in ambient air based on the non-dispersive infrared spectroscopic measuring principle.
This standard describes the performance characteristics and sets the relevant minimum criteria required to select
an appropriate non-dispersive infrared spectroscopic analyser by means of type approval tests. It also includes the
evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements
as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality
assurance for use.
The method is applicable to the determination of the mass concentration of carbon monoxide present in ambient air
up to 100 mg/m3 carbon monoxide. This concentration range represents the certification range for the type
approval test.
Dieses Dokument legt ein kontinuierliches Messverfahren nach dem nicht-dispersiven Infrarot-Messprinzip zur
Bestimmung der Konzentration von Kohlenmonoxid in Außenluft fest. Es nennt die Leistungskenngrößen und
legt die Mindestanforderungen für die Eignungsprüfung von Infrarot-Photometern fest. Es beinhaltet auch die
Bewertung der Eignung eines Messgeräts für den Einsatz an einem bestimmten ortsfesten Messstandort
bezüglich der Anforderungen an die Datenqualität nach Anhang I der Richtlinie 2008/50/EG [1] und bezüglich
der Anforderungen für Probennahme, Kalibrierung und Qualitätssicherung.
Das Verfahren ist anwendbar zur Bestimmung der Massenkonzentration von Kohlenmonoxid in Außenluft bis
100 mg/m3. Dieser Konzentrationsbereich entspricht dem Zertifizierungsbereich für die Eignungsprüfung.