This part of EN 14662 gives general guidance for the sampling and analysis of benzene in air by pumped sampling,
thermal desorption and capillary gas chromatography.
This part of EN 14662 is in accordance with the generic methodology selected as the basis of the European Union
reference method for the determination of benzene in ambient air [1] for the purpose of comparison of
measurement results with limit values with a one-year reference period.
This part of EN 14662 is valid for the measurement of benzene in a concentration range of approximately 0,5 g/m3
to 50 g/m3 in an air sample typically collected over a period of 24 hours.
The upper limit of the useful range is set by the sorptive capacity of the sorbent and by the linear dynamic range of
the gas chromatograph column and detector or by the sample splitting capacity of the analytical instrumentation
used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of benzene
and/or interfering artefacts on the sorbent. Artefacts are typically sub ng for sorbents, but higher levels of aromatic
hydrocarbons have been noted in other sorbents. The detection limit will be approximately 1/10 of the lower
concentration range.
Dieser Teil der EN 14662 ist in Übereinstimmung mit der allgemeinen Methode, die als Grundlage des Referenzverfahrens der Europäischen Union zur Bestimmung der von Benzol in Außenluft gewählt wurde, um die Messergebnisse mit Grenzwerten auf Basis von Jahresmittelwerten zu vergleichen. In diesem Teil werden allgemeine Anleitungen für die Probenahme und Analyse von Benzol in Luft durch Probenahme mit einer Pumpe, Thermodesorption und Kapillar-Gaschromatographie angegeben. Dieser Teil ist anwendbar für die Bestimmung von Benzol in einem Massenkonzentrationsbereich von etwa 0,5 ug/m³ bis 50 ug/m³ in Luftproben, die typischerweise über eine Zeitspanne von 24 h genommen werden.