This European Standard describes a standard method for determining the PM2,5 mass concentration of
suspended particulate matter in ambient air by sampling the particulate matter on filters and weighing them by
means of a balance.
Measurements are made over a sampling period of about 24 h, and in line with the Directive, are expressed
as g/m3, where the volume of air is the volume at ambient conditions near the inlet at the time of sampling.
The range of application of the standard is from 1 g/m3 (i.e. the limit of detection of the standard
measurement method expressed as its uncertainty) up to 120 g/m3 (i.e. the maximum concentration level
observed during the field study undertaken by CEN/TC 264/WG 15 to validate the standard).
NOTE Although the standard is not validated for concentrations over 120 g/m3, its range of application could well be
extended to commonly encountered ambient concentrations up to circa 200 g/m3 when using glass or quartz fibre filters.
At these high concentrations and particulate mass loadings no filter clogging is to be expected. Also the flow rate can be
easily maintained at the nominal setting.
The equivalence procedure in Annex A specifies two approaches, depending on whether the candidate
method differs slightly or fundamentally from the standard method.
In the former case, involving only slight differences from the standard method (variations on a theme) Annex
A provides a restricted procedure to compare only the pertinent differences, instead of a full field test. This
part of the annex serves to give practical guidance for determining equivalence for measurement methods
commonly used in monitoring networks, and includes examples of common variations to the standard method,
such as different filter storing or conditioning procedures and the variation of the standard method for the
application as automated filter changer.
In the latter case, involving a full set of fi (...abbreviated)
Diese Europäische Norm beschreibt eine Referenzmessmethode zur Bestimmung der PM2,5-Massenkonzentration des Schwebstaubes in der Außenluft. Die Probenahme und die Wägung des Staubes erfolgt mit Filtern. Die Messungen werden über eine Probenahmedauer von etwa 24 h durchgeführt. Die Ergebnisse werden gemäß der EU-Richtlinie in µg/m³ ausgedrückt, wobei das Luftvolumen auf das Volumen bei Umgebungsbedingungen nahe dem Probenahmekopf zur Zeit der Probenahme bezogen wird. Die Temperatur und der Druck werden nicht auf Normbedingungen umgerechnet. Der Anwendungsbereich dieser Norm liegt von 1 µg/m³ (das heißt die Nachweisgrenze der Referenzmethode ausgedrückt als deren Unsicherheit) bis zu wenigstens 120 µg/m³.