This European Standard specifies a method for the determination of the boiling range distribution of petroleum
products by capillary gas chromatography using flame ionisation detection. The standard is applicable to
materials having a vapour pressure low enough to permit sampling at ambient temperature, and which have a
boiling range of at least 100 °C. The standard is applicable to materials with initial boiling points (IBP) above
100 °C and final boiling points (FBP) above 750 °C, for example, heavy distillate fuels and residuals. The
method is not applicable to bituminous samples.
The test method is not applicable for the analysis of petroleum or petroleum products containing low molecular
weight components (for example naphthas, reformates, gasolines, diesel). Components containing hetero
atoms (for example alcohols, ethers, acids, or esters) or residue are not to be analyzed by this test method.
NOTE For the purposes of this European Standard, the terms (m/m)and (V/V) are used to represent
respectively the mass fraction and the volume fraction.
WARNING The use of this European Standard may involve hazardous materials, operations and
equipment. This European Standard does not purport to address all of the safety problems associated
with its use. It is the responsibility of the user of this standard to establish appropriate safety and
health practices and to determine the applicability of regulatory limitations prior to use.
ÖNORM EN 15199-2 legt ein Verfahren zur Bestimmung des Siedeverlaufes in Mineralölerzeugnissen mit Hilfe der Kapillar-Gaschromatographie mit einem Flammenionisationsdetektor (FID) fest. Die Norm ist anwendbar auf Mineralölerzeugnisse mit einem für die Probenahme bei Umgebungstemperatur ausreichend niedrigen Dampfdruck und mit einem Siedebereich von mindestens 100 °C. Die Norm ist anwendbar auf Destillate mit einem Siedebeginn (IBP, Initial Boiling Point) oberhalb von 100 °C und mit einem Siedeende (FBP, Final Boiling Point) oberhalb von 750 °C, wie z. B. Schweröle und Rückstandsöle. Für bitumiöse Proben ist dieses Prüfverfahren nicht geeignet.