This document specifies safety, health and functional requirements for 12 V direct current (DC) extra low voltage
(ELV) electrical installations for habitation aspects of caravans. It covers the design and integration of the caravan
system with the towing vehicle system.
It does not apply to commercial trailers, nor does it include requirements for ELV road lighting and signalling lamps
and their installations, except for safety requirements for the routing of cables in LPG storage compartments.
This document also specifies the ELV output requirements of low voltage (LV) equipment that may be used to
provide an ELV supply but it does not specify safety, technical and functional requirements for LV appliances and
installations. Requirements for LV installations are specified in HD 384-7-708.S1.
Dieses Dokument legt die sicherheitstechnischen, gesundheitlichen und funktionellen Anforderungen an elektrische
Anlagen für DC 12 V im Wohnbereich von Caravans fest. Sie beinhaltet die Gestaltung des Caravansystems
und seinen Anschluss an das System des Zugfahrzeugs.
Es gilt nicht für kommerzielle Anhänger und enthält keine Anforderungen an ELV-Straßenlampen, Signallampen
und deren Einbau, außer sicherheitstechnische Anforderungen an die Führung von Leitungen durch Schränke für
die Lagerung von Flüssiggas.
Dieses Dokument legt auch die Anforderungen an die Kleinspannungsleistungsabgabe von Niederspannungs-
(LV-)Geräten fest, die benutzt werden dürfen, um eine Kleinspannungsversorgung zu sichern, aber sie legt nicht
die Sicherheitsanforderungen, technischen und funktionellen Anforderungen an Niederspannungsgeräte und
-anlagen fest. Anforderungen an Niederspannungsanlagen sind in HD 384-7-708.S1 festgelegt.