This document contains specifications for active sampling of bioaerosols from exhaust air flowing through a defined cross-section of a stack. It defines general principles that have to be taken into account during an isokinetic sampling campaign for bioaerosols by bubbling the exhaust air through a specific impinger designed for emission measurements.
In this document the application with culturable organisms is specified but the same principle might be applicable for non-cultural based methods (e.g. molecular and/or enzyme-based methods).
The impinger is designed to allow a sample volume flow of 1 m³/h to 1,8 m³/h, or 16 l/min to 30 l/min, respectively, and has been tested with regard to various microorganisms within broad concentration ranges.
Dieses Dokument enthält Festlegungen zur aktiven Probenahme von Bioaerosolen aus der Abluft, die durch einen definierten Querschnitt eines Abluftkanals strömt. Sie legt allgemeine Grundlagen fest, die bei einer isokinetischen Probenahmekampagne für Bioaerosole berücksichtigt werden müssen, wobei die Abluft durch einen spezifischen Impinger, der auf Emissionsmessungen ausgelegt ist, geleitet wird.
In diesem Dokument wird die Anwendung mit anzüchtbaren Organismen festgelegt, jedoch kann dasselbe Prinzip auch auf Verfahren angewendet werden, die nicht auf Kulturen basieren (z. B. molekulare und/oder enzymbasierte Verfahren).
Der Impinger ist auf einen Teilvolumenstrom von 1 m³/h bis 1,8 m³/h bzw. 16 l/min bis 30 l/min ausgelegt, und wurde für verschiedene Mikroorganismen in breiten Konzentrationsbereichen geprüft.