Каталог стандартов

+7 (495) 223-46-76 +7 (812) 309-78-59
inform@normdocs.ru

ÖNORM EN 253:2013-04

Заменен
District heating pipes - Preinsulated bonded pipe systems for directly buried hot water networks - Pipe assembly of steel service pipe, polyurethane thermal insulation and outer casing of polyethylene
This European Standard specifies requirements and test methods for straight lengths of prefabricated thermally insulated pipe-in-pipe assemblies for directly buried hot water networks, comprising a steel service pipe from DN 15 to DN 1200, rigid polyurethane foam insulation and an outer casing of polyethylene. The pipe assembly may also include the following additional elements: measuring wires, spacers and diffusion barriers. This standard applies only to insulated pipe assemblies, for continuous operation with hot water at various temperatures up to 120 °C and occasionally with a peak temperature up to 140 °C. The estimation of expected thermal life with continuous operation at various temperatures is outlined in Annex B.
Diese Europäische Norm legt Anforderungen und Prüfverfahren für vorgefertigte, gerade wärmegedämmte Rohr-in-Rohr-Systeme für direkt erdverlegte Fernwärmenetze fest, die aus einem Stahl-Mediumrohr von DN 15 bis DN 1200 mit Wärmedämmung aus Polyurethan-Hartschaumstoff und einer Ummantelung aus Polyethylen bestehen. Das Verbund-Rohrsystem darf darüber hinaus folgende Bauteile umfassen: Mess-drähte, Abstandshalter und Diffusionsbarrieren. Diese Norm gilt nur für wärmegedämmte Verbund-Rohrsysteme für den Dauerbetrieb mit Warmwasser bei unterschiedlichen Betriebstemperaturen von bis zu 120 °C und gelegentlich auftretenden Spitzen-temperaturen von bis zu 140 °C. Die Abschätzung der erwarteten thermischen Lebensdauer bei Dauerbetrieb mit unterschiedlichen Betriebs-temperaturen ist in Anhang B erläutert.
ICS
23.040.10 Iron and steel pipes / Чугунные и стальные трубы