This part of IS0 105 describes a method for determining
the dispersibility, as evaluated by filtering time
and filter residue, of disperse dyes.
This test method is used for determining the degree
of dispersion under specified conditions in aqueous
media only.
NOTES
1 The results of this test method can vary widely unless all
tests are run under exactly the conditions outlined. Any
variation in the conditions can cause a test to be invalid.
Results have been shown to be reproducible in several
laboratories when the specified conditions are met.
2 Variations in results can be caused by differences in the
diameter of the filter funnel, due to the differences in surface
area which result, and to variations in the size and
density of the holes in the filter funnel.
Dieser Teil von ISO 105 legt ein Verfahren fest zur Bestimmung des Dispergierverhaltens eines Dispersionsfarbstoffes
durch Bewertung der Filtrationszeit und des Filterrückstandes.
Dieses Prüfverfahren wird zur Bestimmung des Dispergiergrades unter bestimmten Bedingungen nur in
wässrigem Medium angewendet.
ANMERKUNG 1 : Die Ergebnisse des Prüfverfahrens können in weitem Bereich schwanken, wenn nicht
alle Prüfungen unter genau den gleichen Bedingungen durchgeführt werden. Jede Veränderung der
Bedingungen kann Ursache sein, daß die Prüfung ungültig ist. Ergebnisse aus ver schiedenen
Laboratorien erwiesen sich als reproduzierbar, wenn die beschriebenen Bedingungen eingehalten
wurden.
ANMERKUNG 2: Unterschiede im Ergebnis können verursacht werden durch unterschiedlichen Durchmesser
des Filtriertrichters, was sich auf die Oberfläche des Filters auswirkt, und durch Unterschiede
in Ausmaß und Dichte der Löcher im Filtriertrichter.