This document specifies methods for measuring beam widths (diameter), divergence angles and beam propagation ratios of laser beams. This document is applicable to general astigmatic beams or unknown types of beams. For stigmatic and simple astigmatic beams, ISO 11146-1 is applicable.
Within this document, the description of laser beams is accomplished by means of the second order moments of the Wigner distribution rather than physical quantities such as beam widths and divergence angles. However, these physical quantities are closely related to the second order moments of the Wigner distribution. In ISO/TR 11146-3, formulae are given to calculate all relevant physical quantities from the measured second order moments.
Dieses Dokument legt Verfahren zum Messen der Strahlabmessungen (Strahldurchmesser), Divergenzwinkel und Beugungsmaßzahlen von Laserstrahlen fest. Dieses Dokument ist für allgemein astigmatische Strahlen oder Strahlen unbekannter Art anzuwenden. Bei stigmatischen und einfach astigmatischen Strahlen ist ISO 11146-1 anzuwenden.
In diesem Dokument wird die Beschreibung von Laserstrahlen durch die Momente zweiter Ordnung der Wigner-Verteilung gegenüber der Beschreibung durch physikalische Größen wie Strahlabmessungen und Divergenzwinkel bevorzugt. Diese physikalischen Größen stehen jedoch in engem Zusammenhang mit den Momenten zweiter Ordnung der Wigner-Verteilung. In ISO/TR 11146-3 sind Gleichungen zur Berechnung aller relevanten physikalischen Größen aus den Momenten zweiter Ordnung angegeben.