This document specifies a calculation model to estimate the sound insulation or the sound pressure level difference of a façade or other external surface of a building. The calculation is based on the sound reduction index of the different elements from which the façade is constructed and it includes direct and flanking transmission. The calculation gives results which correspond approximately to the results from field measurements in accordance with ISO 16283-3. Calculations can be carried out for frequency bands or for single number ratings.
The calculation results can also be used for calculating the indoor sound pressure level due to for instance road traffic (see Annex E).
This document describes the principles of the calculation model, lists the relevant quantities and defines its applications and restrictions.
Dieses Dokument legt ein Berechnungsmodell zur Ermittlung der Schalldämmung oder der Schalldruckpegeldifferenz einer Fassade oder einer anderen Außenfläche eines Gebäudes fest. Grundlage für die Berechnung ist das Schalldämm-Maß der verschiedenen Fassadenbauteile; sie schließt die Direkt- und Flankenübertragung ein. Die Ergebnisse der Berechnungen korrespondieren annähernd mit den Ergebnissen der nach ISO 16283-3 durchgeführten Messungen unter Baubedingungen. Die Berechnungen können in Frequenzbändern oder als Einzahlangaben ausgeführt werden.
Die Ergebnisse der Berechnungen können auch für die Berechnung des Innen-Schalldruckpegels aufgrund von einwirkendem Straßenverkehrslärm angewendet werden (siehe Anhang E).
In diesem Dokument werden die Grundlagen des Berechnungsmodells beschrieben, die erforderlichen Größen aufgeführt und ihre Anwendungen und Einschränkungen angegeben.