This International Standard specifies the requirements for the
laboratory testing of the resistivity of specially prepared
specimens of plastics rendered conductive by the inclusion of
carbon black. The test is suitable for materials of resistivity less
than 106 Q-cm (104 0m). The result is not strictly a volume
resistivity, because of surface conduction, but the effects of
the latter are generally negligible.
The principle of the four-terminal method of test is mandatory
and the recommended specimen size and electrode design
must be adhered to for reference purposes, but it may
sometimes be necessary to test a wider strip with electrodes of
a different construction.
Diese Internationale Norm legt Anforderungen an die Laboratoriumsprüfung des spezifischen Widerstands von
besonders vorbereiteten Probekörpern aus Kunststoff fest, die durch den Einschluß von Ruß leitfähig gemacht
wurden. Die Prüfung ist für Kunststoffe mit einem spezifischen Widerstand unter 106 R-cm (104 i2.m) geeignet.
Wegen der Oberflächenleitung handelt es sich strenggenommen um keinen spezifischen Durchgangswiderstand;
die Wirkungen der Oberflächenleitung sind jedoch im allgemeinen vernachlässigbar.
Für die Prüfung zwingend vorgeschrieben ist die Anwendung des Vier-Pol-Verfahrens, und für Referenuwecke
müssen die empfohlene Probekörpergröße und Elektrodengestaltung angewandt werden; anderenfalls kann es
jedoch mitunter notwendig sein, einen breiteren Streifen mit Elektroden anderer Ausführung zu prüfen.