Каталог стандартов

+7 (495) 223-46-76 +7 (812) 309-78-59
inform@normdocs.ru

ONR CEN/TS 12007-6:2021-06

Действует
Gas infrastructure - Pipelines for maximum operating pressure up to and including 16 bar - Part 6: Specific functional recommendations for unplasticized polyamide (PA-U) (CEN/TS 12007-6:2021)
This document describes the specific functional requirements for polyamide (PA) pipelines in addition to the general functional requirements of EN 12007-1 for:
a) a maximum operating pressure (MOP) up to and including 16 bar;
b) an operating temperature between -20 °C and +40 °C.
This document covers one type of pipe:
— PA pipes single layer solid wall.
This document specifies common basic principles for gas infrastructure.
CEN/TR 13737 (all parts) give:
— clarification of all legislations/regulations applicable in a member state;
— if appropriate, more restrictive national requirements;
— a national contact point for the latest information.
Dieses Dokument beschreibt, in Ergänzung zu den allgemeinen funktionalen Anforderungen von EN 12007-1, die besonderen funktionalen Anforderungen an Rohrleitungen aus Polyamid (PA) für:
a) einen maximal zulässigen Betriebsdruck (MOP) bis zu 16 bar;
b) und einer Betriebstemperatur von -20 °C und +40 °C.
Dieses Dokument umfasst einen Rohrtyp:
- einschichtige PA-Rohre mit fester Wand.
Dieses Dokument legt gemeinsame Grundprinzipien für die Gasinfrastruktur fest.
CEN/TR 13737 (alle Teile) enthält
- eine Klarstellung aller geltenden Rechtsvorschriften/Bestimmungen eines Mitgliedsstaats;
- ggf. weitergehende strengere nationale Anforderungen;
- einen nationalen Ansprechpartner für die Weitergabe neuester Informationen.
ICS
23.040.20 Plastics pipes / Пластмассовые трубы