This part specifies requirements for fire detection, alarm systems, equipment shutdown, information and
communication systems, emergency lighting, emergency brake systems and fire fighting systems to cover the
objectives defined in CEN/TS 45545-1.
The measures and requirements specified in this Technical Specification aim to protect passengers and staff
in railway vehicles in the event of a fire on board by alerting staff and passengers to a fire, delaying the fire
development and controlling the movement of smoke.
It is not within the scope of this Technical Specification to describe measures that ensure the preservation of
the vehicles in the event of a fire.
This part is valid for railway vehicles defined in CEN/TS 45545-1.
2
In diesem Teil sind die Anforderungen an Brandmeldung, Alarmsysteme, Abschaltung von Einrichtungen,
Informations- und Kommunikationssysteme, Notbeleuchtung, Notbremse und Brandbekämpfungseinrichtungen
spezifiziert, um die in CEN/TS 45545-1 definierten Ziele abzudecken.
Die in dieser Technischen Spezifikation beschriebenen Maßnahmen und Anforderungen haben zum Ziel,
Fahrgäste und Personal in Schienenfahrzeugen im Falle eines Brandes an Bord zu schützen, durch
Alarmierung von Personal und Fahrgästen sowie durch Verzögerung der Brandentwicklung und Steuerung
der Rauchausbreitung.
Maßnahmen, die die Erhaltung der Fahrzeuge im Brandfall sicherstellen, gehören nicht zum Anwendungsbereich
dieser Technischen Spezifikation.
Dieser Teil gilt für Schienenfahrzeuge nach CEN/TS 45545-1.