This Part 512 of IEC 60811 describes the procedure for testing tensile strength and
elongation at break after conditioning at elevated temperature. It is specific to polyethylene
and polypropylene compounds.
This test is intended for samples from filled cables, of polyolefin insulations with a wall
thickness of more than 0,8 mm and for polyolefin sheaths in direct contact with filling
compound.