Non-invasive sphygmomanometers - Part 1: Requirements and test methods for non-automated measurement type (ISO 81060-1:2007)
Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment (ISO 80601-2-61:2017, corrected version 2018-02)
OVE EN 60601-2-23:2016-09
Действует
Medical electrical equipment -- Part 2-23: Particular requirements for the basic safety and essential performance of transcutaneous partial pressure monitoring equipment (IEC 60601-2-23:2011) (english version)
OVE EN 60601-2-37:2016-12
Действует
Medical electrical equipment -- Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment (IEC 60601-2-37:2007) (english version)
Medical electrical equipment -- Part 2-26: Particular requirements for the basic safety and essential performance of electroencephalographs (IEC 60601-2-26:2012) (english version)
Ultrasonics - Pulse-echo scanners - Part 2: Measurement of maximum depth of penetration and local dynamic range (IEC 61391-2:2010) (english version)
Medical electrical equipment -- Part 2-47: Particular requirements for the basic safety and essential performance of ambulatory electrocardiographic systems (IEC 60601-2-47:2012) (english version)
Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiology (IEC 61676:2002/A1:2008) (Amendment)
Medical electrical equipment - Part 2-34: Particular requirements for the basic safety and essential performance of invasive blood pressure monitoring equipment (IEC 60601-2-34:2011) (english version)
Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment (IEC 60601-2-22:2007) (english version)
Medical electrical equipment - Medical image display systems - Part 1: Evaluation methods (IEC 62563-1:2009) (english version)
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment (IEC 61326-2-6:2012) (english version)
Medical electrical equipment -- Part 2-41: Particular requirements for basic safety and essential performance of surgical luminaires and luminaires for diagnosis(IEC 60601-2-41:2009 + A1:2013) (english version)
Standard means for the reporting of the acoustic output of medical diagnostic ultrasonic equipment (IEC 61157:2007 + A1:2013) (english version)
Medical electrical equipment Part 1-8: General requirements for basic safety and essential performance - Collateral Standard: General requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems (IEC 60601-1-8:2006 + A1:2012) (english version)
Magnetic resonance equipment for medical imaging - Part 2: Classification criteria for pulse sequences (IEC 62464-2:2010)
Health informatics - Personal health device communication - Part 00103: Overview (ISO/IEEE 11073-00103:2015)
Health informatics - Personal health device communication - Part 10421: Device specialization - Peak expiratory flow monitor (peak flow) (ISO/IEEE 11073-10421:2012)
Health informatics - Personal health device communication - Part 10441: Device specialization - Cardiovascular fitness and activity monitor (ISO/IEEE 11073-10441:2015)
In vitro diagnostic medical devices - Information supplied by the manufacturer with in vitro diagnostic reagents for staining in biology (ISO 19001:2013)