4.1 This test measures the trace level amount of sediment that is naphtha-insoluble and can be separated by centrifuging. Excessive amounts of sediment in oil could lead to system malfunction in critical applications.
Область применения1.1 This test method covers the determination of trace amounts (less than 0.05 volume %) of sediment in lubricating oils. Since oil-soluble material precipitated by the specified solvent is not intended as part of the measured sediment, the test method is not applicable in cases where precipitated oil-soluble components will appreciably contribute to the sediment readings.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.