ASTM F1689-05(2012)

Заменен
Standard Test Method for Determining the Insulation Resistance of a Membrane Switch — 2 стр.
Значение и использование

Insulation resistance is useful for design verification, quality control of materials, and workmanship.

Low insulation resistance can cause high leakage currents.

High leakage currents can lead to deterioration of the insulation or false triggering of the associated input device, or both.

Specific areas of testing are, but not limited to:

Conductor/dielectric/conductor crossing point.

Close proximity of conductors, and

Any other conductive surface such as shielding or metal backing panel.

Insulation resistance measurement may be destructive and units that have been tested should be considered unreliable for future use.

Область применения

1.1 This test method covers the determination of the insulation resistance of a membrane switch.

1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ICS
17.220.20 Measurement. Including measuring instruments, instrument transformers / Измерения электрических и магнитных величин. Включая измерительные приборы, измерительные трансформаторы
29.120.40 Switches / Переключатели
Сборник ASTM
10.04 Electronics; Declarable Substances in Materials; 3D Imaging Systems; Additive Manufacturing Technologies / Электроника; Декларируемые вещества в материалах; Системы 3D-визуализации; Аддитивные технологии производства
Тематика
Electronics