Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not exceeding a net heat input of 70 kW
This European Standard specifies the requirements and test methods for the safety and efficiency of domestic
gas-fired air heaters with a fan to assist the transportation of combustion air and/or combustion products,
hereafter referred to as appliances.
This European Standard applies to Type B12, B12AS, B12BS, B13, B13AS, B13BS, B14, B14AS, B14BS, B22, B23, B42,
B42AS, B42BS, B43, B43AS, B43BS, B44, B44AS, B44BS, B52, B53, C12, C13, C32, C33, C62 and C63 appliances with an input
not exceeding 70 kW (net cv basis), intended primarily for use in single unit residential dwellings. Provision of
the heated air may be by means of ducting.
Diese Europäische Norm legt die Anforderungen an und Prüfverfahren für die Sicherheit und Leistungsfähigkeit
gasbefeuerter Warmlufterzeuger für den häuslichen Gebrauch mit einem Gebläse zur Beförderung
der Verbrennungsluft und/oder des Rauchgases (nachfolgend kurz ¿Geräte¿ genannt) fest.
Diese Europäische Norm gilt für Geräte der Bauarten B12, B12AS, B12BS, B13, B13AS, B13BS, B14, B14AS,
B14BS, B22, B23, B42, B42AS, B42BS, B43, B43AS, B43BS, B44, B44AS, B44BS, B52, B53, C12, C13, C32, C33, C62
und C63, deren Wärmebelastung 70 kW (bezogen auf den Heizwert) nicht übersteigt, und die hauptsächlich
für den Gebrauch in aus nur einer Einheit bestehenden Wohnungen bestimmt sind. Die Abgabe der Warmluft
kann durch Leitungen erfolgen.